The sensitivity matrix is main part of the image reconstruction process for 3D ECT imaging and strictly decides about the its final quality. Common sensitivity determination methods mostly provide acceptable results and additionally allow to perform the recalculation of the sensitivities according to the changing permittivity distribution. In this paper authors introduce the crucial modification of the sensitivity determination process based on the electric field distribution analysis. The designed new tunnel based algorithm follows the surfaces constructed along the electric field lines. In the paper the results of the image reconstruction experiments will be shown and the better accuracy of the new method will be proved.
References
Banasiak R.: Algorytmy wizualizacji 3D w przemysłowych systemach elektrycznej tomografii procesowej; Praca doktorska, Politechnika Łódzka, Łódź, 2007
Banasiak R., Wajman R., Sankowski D., Soleimani M.: Three-dimensional nonlinear inversion of electrical capacitance tomography data using a complete sensor model, Progress In Electromagnetics Research PIER, 100, (2010), pp. 219-234
Dyakowski T.: Process tomography applied to multi-phase flow measurement, Meas. Sci. Technol. 7 (1996) pp. 343–353
Loser T., Wajman R., Mewes D. 2001 Electrical capacitance tomography: image reconstruction along electrical field lines, Meas. Sci. Technol. 2001, vol. 12 nr 8 (2001), pp. 1083-1091
Olszewski T., Kleczyński P., Brzeski P., Mirkowski J., Pląskowski A., Smolik W., Szabatin R. (2004) Electrical capacitance tomograph design; 3rd International Symposium on Process Tomography in Poland, Łódź, str. 118-123
Rząsa M.R. (2004) The Stand For Tests of Gas-Liquid Flow Structure; 3rd International Symposium on Process Tomography in Poland, Łódź, str. 139-142
Sikora J. (2000) Algorytmy numeryczne w tomografii impedancyjnej. Oficyna Wydawnicza Politechniki Warszawskiej, W-wa
Wajman R.: Nowa metoda rekonstrukcji obrazów dla potrzeb pojemnościowej tomografii procesowej, Praca doktorska, Politechnika Łódzka, Łódź, 2006
Wang H.G., Liu S., Jiang F., Yang W.Q. (2003) 3D Presentation of Images with Capacitance Tomography; 3rd World Congress on Industrial Process Tomography, Banff, Canada; str. 331-336
Williams R.A., Beck M.S. (1995) Process tomography: principles, techniques and applications. BH, Oxford
Xie C.G., Huang S.M., Hayes D.G., Gregory I.A., Beck C.M.: Transputer/DSP-based capacitance tomography for real-time imaging and velocity profile measurement of oilfield flow pipelines; Parallel Computing and Transputer Appl., Edts. M.S. Beck u.a., (1994) pp. 123-134
Yang W.Q. and Peng L.: Review of image reconstruction algorithms for electrical capacitance tomography, Part 1, Principles, proc International Symposium on Process Tomography in Poland (Wrocław), 2002, pp. 123-132
Yang W.Q., Peng L.: Image reconstruction algorithms for electrical capacitance tomography; Meas. Sci. Technol. 2003, Vol. 14, No. 1, pp. R1-R13
Zienkiewicz O.C. (1972) Metoda Elementów Skończonych; Arkady Warszawa