Mateusz Midura
mmidura@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, Institute of Radioelectronics and Multimedia Technology, Division of Medical and Nuclear Electronics
Poland
Przemysław Wróblewski
P.Wroblewski@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, Institute of Radioelectronics and Multimedia Technology, Division of Medical and Nuclear Electronics
Poland
Damian Wanta
D.Wanta@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, Institute of Radioelectronics and Multimedia Technology, Division of Medical and Nuclear Electronics
Poland
Grzegorz Domański
G.Domanski@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, Institute of Radioelectronics and Multimedia Technology, Division of Medical and Nuclear Electronics
Poland
Mateusz Stosio
M.Stosio@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, Institute of Radioelectronics and Multimedia Technology, Division of Medical and Nuclear Electronics
Poland
Jacek Kryszyn
J.Kryszyn@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, Institute of Radioelectronics and Multimedia Technology, Division of Medical and Nuclear Electronics
Poland
Waldemar T. Smolik
W.Smolik@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, Institute of Radioelectronics and Multimedia Technology, Division of Medical and Nuclear Electronics
Poland
The article concerns the research on the properties of core-shell superparamagnetic nanoparticles in the context of their use in medicine for diagnostics and therapy. The article presents a system for impedance (AC) spectroscopy of nanoparticles with a new arrangement of receive coils. A significant modification was the position of the reference coil in relation to the receive coils as well as the method of winding and routing the wires on the carcass. The 3D printing technique was used in the production of the measuring coil system. The aim of the work was to experimentally verify the developed measurement system and analyze its properties. The system tests were carried out at low frequencies ranging from 2 to 50 kHz. Complex magnetic susceptibility was measured for superparamagnetic iron oxide nanoparticles in polymer shells in a physiological saline solution. The obtained results confirmed the relevance of the concept of the measurements. In summary, the observed properties of the realized system are discussed and further directions of its development are proposed.
References
Bogren S. et al.: Classification of Magnetic Nanoparticle Systems–Synthesis, Standardization and Analysis Methods in the NanoMag Project. International Journal of Molecular Sciences 16(9)/2015, 20308–20325 [http://doi.org/10.3390/ijms160920308].
Graeser M. et al.: Analog receive signal processing for magnetic particle imaging. Med. Phys. 40(4)/2013, 042303 [http://doi.org/10.1118/1.4794482].
Harabech M. et al.: The Effect of the Magnetic Nanoparticle’s Size Dependence of the Relaxation Time Constant on the Specific Loss Power of Magnetic Nanoparticle Hyperthermia. Journal of Magnetism and Magnetic Materials 426/2017, 206–210 [http://doi.org/10.1016/j.jmmm.2016.11.079].
Hergt R. et al.: Magnetic Particle Hyperthermia: Nanoparticle Magnetism and Materials Development for Cancer Therapy. Journal of Physics Condensed Matter 18(38)/2006, S2919 [http://doi.org/10.1088/0953-8984/18/38/S26].
Kishore K., Akbar S. A.: Evolution of Lock-In Amplifier as Portable Sensor Interface Platform: A Review. IEEE Sensors Journal 20(18)/2020, 10345–10354 [http://doi.org/10.1109/JSEN.2020.2993309].
Ludwig F. et al.: Analysis of AC Susceptibility Spectra for the Characterization of Magnetic Nanoparticles. IEEE Transactions on Magnetics 53(11)/2017, 10–13 [http://doi.org/10.1109/TMAG.2017.2693420].
Mahdavi Z. et al.: Core-Shell Nanoparticles Used in Drug Delivery-Microfluidics: A Review. RSC Advances 10(31)/2020, 18280–18295 [http://doi.org/10.1039/d0ra01032d].
Maity D., Ganeshlenin K.: Superparamagnetic Nanoparticles for Cancer Hyperthermia Treatment. Nanotechnology Characterization Tools for Tissue Engineering and Medical Therapy, Springer Berlin Heidelberg, 2019, 299–332 [http://doi.org/10.1007/978-3-662-59596-1_7].
Reeves D. B., Weaver J. B.: Magnetic Nanoparticle Sensing: Decoupling the Magnetization from the Excitation Field. Journal of Physics D: Applied Physics 47(4)/2013, 45002 [http://doi.org/10.1088/0022-3727/47/4/045002].
Sandler S. E. et al.: Best Practices for Characterization of Magnetic Nanoparticles for Biomedical Applications. Analytical Chemistry 91(22)/2019, 14159–14169 [http://doi.org/10.1021/acs.analchem.9b03518].
Šouc J. et al.: Calibration Free Method for Measurement of the AC Magnetization Loss. Superconductor Science and Technology 18(5)/2005, 592–595 [http://doi.org/10.1088/0953-2048/18/5/003].
Suhaimi N. S. et al.: A Resonant Type AC Magnetometer for Evaluation of Magnetic Nanoparticles. Hassan M. (eds) Intelligent Manufacturing & Mechatronics. Lecture Notes in Mechanical Engineering. Springer, Singapore 2018 [http://doi.org/10.1007/978-981-10-8788-2_9].
Sun Y. et al.: An Improved Method for Estimating Core Size Distributions of Magnetic Nanoparticles via Magnetization Harmonics. Nanomaterials 10(9)/2020, 1–12 [http://doi.org/10.3390/nano10091623].
Valentini M. et al.: Diffusion NMR Spectroscopy for the Characterization of the Size and Interactions of Colloidal Matter: The Case of Vesicles and Nanoparticles. Journal of the American Chemical Society 126(7)/2004, 2142–2147 [http://doi.org/10.1021/ja037247r].
Vallejo-Fernandez G. et al.: Mechanisms of Hyperthermia in Magnetic Nanoparticles. Journal of Physics D: Applied Physics 46(31)/2013 [http://doi.org/10.1088/0022-3727/46/31/312001].
Van De Loosdrecht M. M. et al.: A Novel Characterization Technique for Superparamagnetic Iron Oxide Nanoparticles: The Superparamagnetic Quantifier, Compared with Magnetic Particle Spectroscopy. Review of Scientific Instruments 90(2)/2019 [http://doi.org/10.1063/1.5039150].
Wróblewski P., Smolik W.: Coil design with litze wire for magnetic particle spectrometry. Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska 7(1)/2017, 150–153 [http://doi.org/10.5604/01.3001.0010.4605].
Wu K. et al.: Magnetic Particle Spectroscopy: A Short Review of Applications Using Magnetic Nanoparticles. ACS Applied Nano Materials 3(6)/2020, 4972–89 [http://doi.org/10.1021/acsanm.0c00890].
Yang T. Q. et al.: Detection of Magnetic Nanoparticles with Ac Susceptibility Measurement. Physica C: Superconductivity and Its Applications 412–414/2004, 1496–1500 [http://doi.org/10.1016/j.physc.2004.01.146].
Quantum Design, MPMS Application Note 1070-207: Using PPMS Superconducting Magnets at Low Fields 2009.