Prolonged exposure to elevated temperatures exceeding 47°C, which can occur during root canal obturation, can cause damage of both dental and bone tissues. In order to study the temperature distribution on the surface of the tooth root a temperature measuring device with cold-junction compensation is proposed. For in vitro measurement of the temperature distribution on the surface of the tooth, 8 thermocouples placed in direct contact with the cementum of the tooth were used. In order to eliminate the cold-junction temperature variations, the temperature equilibration device and RTD were used. The suggested linear approximation for the thermocouples' conversion function provides a nonlinearity relative error of less than 0.05% for K-type thermocouples and 0.07% for J-type thermocouples over the temperature range from 20 to 60°C.
References
Anandanatarajan R., Mangalanathan U., Gandhi U.: Deep Neural Network-Based Linearization and Cold Junction Compensation of Thermocouple. IEEE Transactions on Instrumentation and Measurement 72, 2022, 1–9.
Balagopal S. et al.: Evaluation of remaining dentin thickness around the prepared root canals and its influence on the temperature changes on the external root surfaces during different heated gutta-percha obturation techniques. Indian Journal of Dental Research 31(6), 2020, 857–861.
Bhandi S. et al.: Complete obturation–cold lateral condensation vs. thermoplastic techniques: a systematic review of micro-CT studies. Materials 14(14), 2021, 4013.
Boyko O., Hotra O.: Improvement of dynamic characteristics of thermoresistive transducers with controlled heating, Przegląd elektrotechniczny 2019(5), 2019, 110–113.
Diegritz C., Gerlitzki O., Fotiadou C., Folwaczny M.: Temperature changes on the root surface during application of warm vertical compaction using three different obturation units. Odontology 108, 2020, 358–365.
Donnermeyer D., Schäfer E., Bürklein S.: Real-time intracanal temperature measurement during different obturation techniques. Journal of endodontics 44(12), 2018, 1832–1836.
Epley S. R., Fleischman J., Hartwell G., Cicalese C.: Completeness of Root Canal Obturations: Epiphany Techniques versus Gutta-Percha Techniques. J. Endod. 32, 2006, 541–544.
García-Cuerva M. et al.: Root surface temperature variation during mechanical removal of root canal filling material. An in vitro study. Acta odontologica latinoamericana – AOL 30(1), 2017.
Hotra O.: Microprocessor temperature meter for dentistry investigation. Przegląd Elektrotechniczny 86 (7), 2010, 63–65.
Hotra O.: Transistor-based temperature measuring device. Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska – IAPGOS 10(2), 2020, 4–7.
Hotra O., Boyko O., Zyska T.: Improvement of the operation rate of medical temperature measuring devices. Proc. SPIE 92914, 2014, 92910A-92910A–6.
Hotra O., Boyko O.: Analogue linearization of transfer function of resistive temperature transducers. Proc. SPIE 9662, 2015, 966247-966247–8.
Hotra O., Boyko O.: Compensation bridge circuit with temperature-dependent voltage divider. Przeglad elektrotechniczny 4a, 2012, 169–171.
Izhar U., Piyathilaka L., Preethichandra D. M. G.: Sensors for brain temperature measurement and monitoring–a review. Neuroscience Informatics 2(4), 2022, 100106.
Lee F. S., Van-Cura J. E., Begole E. A.: A comparison of root surface temperatures using different obturation heat sources. Journal of Endodentistry 24, 1998, 617–620.
Maseko M. L., Agee J. T., Davidson I.: Thermocouple signal conditioning using augmented device tables and table look-up neural networks, with validation in J-Thermocouples. IEEE 30th Southern African Universities Power Engineering Conference – SAUPEC, 2022, 1–4.
Mena-Álvarez J. et al.: Comparative Analysis of Temperature Variation with Three Continuous Wave Obturation Systems in Endodontics: An In Vitro Study. Applied Sciences 12(12), 2022, 6229.
Mukherjee A. et al.: An analog signal conditioning circuit for thermocouple temperature sensor employing thermistor for cold junction compensation. International conference on control, automation, robotics and embedded systems (care) 2013, 1–5.
Radeva E. et al.: Evaluation of the apical seal after post space preparation: in vitro study. Journal of IMAB–Annual Proceeding Scientific Papers 25(1), 2019, 2327–2331.
Radeva E. et al.: Temperature changes on the external root surface during post space preparation (in vitro study). Journal of IMAB–Annual Proceeding Scientific Papers 23(4), 2017, 1839–1844.
Seung M., Choi W., Hur S., Kwon I.: Cold Junction Compensation Technique of Thermocouple Thermometer Using Radiation-Hardened-by-Design Voltage Reference for Harsh Radiation Environment. IEEE Transactions on Instrumentation and Measurement 71, 2022, 1–7.
Simeone M. et al.: Temperature Profiles Along the Root with Gutta-percha Warmed through Different Heat Sources. The Open Dentistry Journal 8, 2014, 229.
Singla M., Aggarwal V., Sinha N.: External root surface temperature changes during high-temperature injectable thermoplasticized root canal obturation in simulated immature teeth. Saudi Endodontic Journal 10(1), 2020, 51–55.
Sivakumar A. A. et al.: Evaluation of temperature change in the root surface during post space preparation using two different drill systems – An invitro study. IOSR Journal of Dental and Medical Sciences 20 (10), 2021, 01–06.
Wei G., Wang X., Sun J.: Signal processing method with cold junction compensation for thermocouple. IEEE Instrumentation and Measurement Technology Conference 2009, 1458–1462.
Weller R. N. et al., A new model system for measuring intra-canal temperatures. Journal of Endodentistry 17, 1991, 491–494.