The article addresses the implementation of projects for new digital substations, as well as upgrading existing substations using digital intelligent electronic devices. The purpose of the scientific article is to implement the GOOSE protocol into the IEC 61850 standard, enabling all substation process equipment to be interconnected with a single information network. These technological advancements significantly influence the process of operating secondary equipment at substations and, at first, may pose certain challenges during its testing. The experimental analysis confirmed that the mechanism of cyclic transmission of GOOSE messages in REF615 and SEPAM T62 devices operates in accordance with the protocol. The repeated transmission mechanism ensures message delivery and enables detection of communication failures after the maximum period of transmission of GOOSE messages.
Keywords:
distribution substation, logical nodes, signal identification, control, monitoring, program
References
[1] Akimzhanov T. et al.: Identifying the Influence of the System and Mode Characteristics on the Power Loss Mode Based in 110 kV Power Grids. Eastern-European Journal of Enterprise Technologies 6(8-126), 2023, 6–14.
[2] Bernd D., Seidler S.: Digital substation as an intelligent agent for unattended substations. VELC-2011 Modern Intelligent Electric Power Systems 2, 2011, 130–135.
[3] Denisenko V.V.: Computer control of the technological process, experiment, equipment. Hot Line. Telecom, Moscow 2009.
[4] Gorelik T. G., Kirienko O. V.: Design issues of the substation automation and control systems based on the IEC61850 standard. International scientific and technical conference "Modern directions of the relay protection and automation systems development in power systems" SIGRE-2013, 3-7.06.2013, Ekaterinburg, 2013.
[5] Gribakin N. S.: Practice of the IEC61850 standard application at the electric power industry objects. Automation and IT in power engineering 10, 2010, 50–54.
[6] Issabekov Z. B., et al.: Configurations of 6-10 kV cable lines and types of cable damages. AIP Conference Proceedings 030002, 2021, 23–37.
[7] Orlov L.: Experience of designing and implementation of relay protection and automatic control systems based on IEC 61850 technology. Automation and IT in power engineering 1, 2010, 48–51.
[8] Zhantlessova A., et al.: Instrumental Research on the Voltage Harmonic Distortion Coefficient in the Modern 110 kV Urban Electric Network. International Journal on Energy Conversion 11(2), 2023, 56–63.