APPLICATION OF LOW-COST PARTICULATE MATTER SENSORS FOR MEASUREMENT OF POLLUTANTS GENERATED DURING 3D PRINTING

Main Article Content

Jarosław Tatarczak

j.tatarczak@pollub.pl

Abstract

This work presents measurement results of pollutants generated during 3D printing. The measure of pollutants is the concentration of particulate matter with a diameter of up to 2.5 μm (PM2,5). Materials acrylonitrile-butadiene-styrene (ABS), polyactide (PLA) for a 3D printer and low-cost particulate matter concentration sensors PMS3003, PMS7003 were used in the research. Research results show that  low-cost sensors can be useful for monitoring pollution during 3D printing in offices, laboratories or private homes.

Keywords:

3D printing, particulate matter, pollution measurement, low-cost sensor

References

Article Details