OPTYCZNY CZUJNIK FLAWONOIDÓW BAZUJĄCY NA CIEKŁYCH KRYSZTAŁACH

Orest Sushynskyi

orest.y.sushynskyi@lpnu.ua
Lviv Polytechnic National University, Department of Electronic Devices (Ukraina)
http://orcid.org/0000-0002-2661-6458

Romana Petrina


Lviv Polytechnic National University, Department of Technology of Biologically Active Substances, Pharmacy and Biotechnology (Ukraina)
http://orcid.org/0000-0002-5416-1999

Zoriana Gubriy


Lviv Polytechnic National University, Department of Technology of Biologically Active Substances, Pharmacy and Biotechnology (Ukraina)
http://orcid.org/0000-0003-2533-6857

Semen Khomyak


Lviv Polytechnic National University, Department of Technology of Biologically Active Substances, Pharmacy and Biotechnology (Ukraina)
http://orcid.org/0000-0003-1931-1688

Zinoviy Mykytyuk


Lviv Polytechnic National University, Department of Electronic Devices (Ukraina)
http://orcid.org/0000-0002-1944-2015

Volodymyr Novikov


Lviv Polytechnic National University, Department of Technology of Biologically Active Substances, Pharmacy and Biotechnology (Ukraina)
http://orcid.org/0000-0002-0485-8720

Abstrakt

Aby rozwiązać problemy związane z szybką analizą obecności substancji biologicznie czynnych w biomasie kalusa, proponujemy zastosowanie materiałów ciekłokrystalicznych o spiralnej strukturze supramolekularnej jako wrażliwego elementu czujnika optycznego flawonoidów. Proponuje się stosowanie cholesterycznego ciekłego kryształu BLO62 jako wrażliwego elementu. Uzyskano charakterystykę spektralną roztworów alkoholowych flawonoidów (20%, 40%, 70% i 90%). Przeanalizowano interakcję cholesterycznego ciekłego kryształu z kwercetyną. Opracowano schemat pierwotnego przetwornika sygnału, w którym prąd z fotodetektora jest przesyłany do opracowanego przetwornika sygnałów. Urządzenie jest realizowane na bazie mikrokontrolera Atmega32 Atmega 328. Cechą tego schematu strukturalnego jest jego elastyczność i wszechstronność, co ułatwia rekonfigurację parametrów oprogramowania do rejestracji różnych typów badanych substancji.


Słowa kluczowe:

czujnik optyczny, ciekły kryształ, flawonoidy, kwercetyna

Barylo G., Holyaka R., Prudyus I., Fabirovskyy S.: Parametric analysis of galvanostatic type impedance measuring front-end. Proceedings of the 4th International scientific-practical conference problems of infocommunications–science and technology PIC S&T, Kharkiv 2017, 323–326.
  Google Scholar

Barylo G., Holyaka R., Virt V., Vezyr F.: Method of analysis errors of measuring conversion of impedance spectroscopy with activation nonharmonic signals. Scientific Journal of the Ternopil National Technical University 86/2017, 108–116.
  Google Scholar

Barylo G., Mykytyuk Z., Holyaka R., Vistak M., Virt V., Vezyr F.: Parametric analysis of input circuits of galvanostatic type impedance measuring transducers. Sensors & Transducers 214/2017, 64–68.
  Google Scholar

Barylo G.I., Holyaka R.L., Virt V.V., Vezyr F.F.: Parametric analysis of synchronous detector devices of impedance spectroscopy. Scientific and technical journal Applied radio electronics 16/2017, 41–45.
  Google Scholar

Bashtyk Y., Bojko O., Fechan A., Grzyb P., Turyk P.: Primary converters for optical sensors of physical values based on polymer dispersed cholesteric liquid crystal. Molecular Crystals and Liquid Crystals, 642/2017, 41–46 [DOI: 10.1080/15421406.2016.1254509].
  Google Scholar

Bishchaniuk T.M., Balaban O.V., Shvets R.Y., Grygorchak I.I., Fechan A.V., Lukiyanets B.A., Ivashchyshyn F.O.: Electronic processes and energy storage in inorganic/organic nanohybrids. Molecular Crystals and Liquid Crystals 589/2014, 132–140 [DOI: 10.1080/15421406.2013.872404].
  Google Scholar

Dudok T.H., Savaryn V.I., Krupych O.M., Fechan A.V., Lychkovskyy E., Cherpak V.V., Pansu B., Nastishin Y.A.: Lasing in imperfectly aligned cholesterics. Applied Optics 54/2015, 9644–9653 [DOI: 10.1364/AO.54.009644].
  Google Scholar

Kobsar А.Ya.: Pharmacognosy in medicine. Medecine, Kyiv 2007.
  Google Scholar

Konechna R., Khropot O., Petrina R., Kurka M., Gubriy Z., Novikov V.: Research of antioxidant properties of extracts of the plants and the callus biomass. Asian Journal of Pharmaceutical and Clinical Research 10/2017, 182–185.
  Google Scholar

Konechna R.T, Petrina R.O.: Extracts of callus and vegetative raw materials Arnica montana L. Pharmaceutical Clinical Pharmacy, Pharmacotherapy and Medical Standardization 1/2015, 100–104.
  Google Scholar

Mikityuk Z., Fechan A., Semenova J.: Liquid crystal material for light modulators on the base of cholesteric-nematic phase transition. Proceedings of SPIE – The International Society for Optical Engineering, Electronic Imaging: Science & Technology, 1996. 196–208 [DOI: 10.1117/12.235353].
  Google Scholar

Mykytyuk Z., Fechan A., Petryshak V., Barylo G., Boyko O.: Optoelectronic multi-sensor of SO2 and NO2 gases. Proceedings of 13th International Conference on Modern Problems of Radio Engineering, Telecommunications and Computer Science TCSET, Lviv 2016, 402–405 [DOI: 2016.7452070].
  Google Scholar

Nad` B. B.: Bioecological and biotechnological bases for preservation of the gene pool Arnica montana L. in Transcarpathia. Тimpani, Uzhhorod – Berehove 2014.
  Google Scholar

Pokorny J.: Application of phenolic antioxidants in food products. EJEAF Chem. 7/2008, 3320–3324.
  Google Scholar

Sushynskyi O., Prystay T., Mykytyuk Z.: The nanocomposite on the base of liquid crystal material with aluminum nitride for sulfur dioxide optical sensor. Proceedings of SID International Symposium Digest of Technical Papers EuroDisplay, 2015, 92 [DOI:92 10.1002/sdtp.10507].
  Google Scholar

Sushynskyi O., Vistak M., Dmytrah V.: The sensitive element of primary transducer of protein optical sensor. Proceedings of the 13th International Conference Modern Problems of Radio Engineering, Telecommunications and Computer Science, TCSET, Lviv 2016 418–421.
  Google Scholar

Vistak M., Dmytrah V., Horbenko Ju.: Investigation of spectral characteristics of cholesteric liquid crystals at carbohydrates influence. Eastern European Journal of Enterprise Technologies 6/2016, 18–22 [DOI:10.15587/1729-4061.2015.65481].
  Google Scholar

Vistak M., Dmytrah V., Mykytyuk Z., Petryshak V., Horbenko Y.: A liquid crystal-based sensitive element for optical sensors of cholesterol. Functional Materials 24/2017, 687–691 [DOI: 10.15407/fm24.04.687].
  Google Scholar


Opublikowane
2019-03-03

Cited By / Share

Sushynskyi, O., Petrina, R., Gubriy, Z., Khomyak, S., Mykytyuk , Z., & Novikov, V. (2019). OPTYCZNY CZUJNIK FLAWONOIDÓW BAZUJĄCY NA CIEKŁYCH KRYSZTAŁACH. Informatyka, Automatyka, Pomiary W Gospodarce I Ochronie Środowiska, 9(1), 61–64. https://doi.org/10.5604/01.3001.0013.0934

Autorzy

Orest Sushynskyi 
orest.y.sushynskyi@lpnu.ua
Lviv Polytechnic National University, Department of Electronic Devices Ukraina
http://orcid.org/0000-0002-2661-6458

Autorzy

Romana Petrina 

Lviv Polytechnic National University, Department of Technology of Biologically Active Substances, Pharmacy and Biotechnology Ukraina
http://orcid.org/0000-0002-5416-1999

Autorzy

Zoriana Gubriy 

Lviv Polytechnic National University, Department of Technology of Biologically Active Substances, Pharmacy and Biotechnology Ukraina
http://orcid.org/0000-0003-2533-6857

Autorzy

Semen Khomyak 

Lviv Polytechnic National University, Department of Technology of Biologically Active Substances, Pharmacy and Biotechnology Ukraina
http://orcid.org/0000-0003-1931-1688

Autorzy

Zinoviy Mykytyuk  

Lviv Polytechnic National University, Department of Electronic Devices Ukraina
http://orcid.org/0000-0002-1944-2015

Autorzy

Volodymyr Novikov 

Lviv Polytechnic National University, Department of Technology of Biologically Active Substances, Pharmacy and Biotechnology Ukraina
http://orcid.org/0000-0002-0485-8720

Statystyki

Abstract views: 196
PDF downloads: 8364