Recording using a motion capture system and a mobile device with synchronization of the recording triggering

Karol Walczyna

karolwalczyna@outlook.com
Lublin University of Technology (Poland)

Bartosz Jasiński


Lublin University of Technology (Poland)

Jakub Smołka


Lublin University of Technology (Poland)

Mateusz Miziołek


Lublin University of Technology (Poland)

Abstract

The main problem during research with a motion capture system and mobile device is lack of possibility to simultaneously begin recording on the motion capture system and a mobile device. Two methods were developed to solve this problem. In the first method the recording is started on the mobile phone and the motion capture system is notified, in the second method the motion capture system starts recording and notifies the mobile device. Both of them were compared for lags and correlation of data form the mobile device and the motion
capture system.


Keywords:

Vicon Nexus; motion capture; synchronization

[1] Pascu T., White M., Patoli Z.: Motion capture and activity tracking using smartphone-driven body sensor networks, Third International Conference on Innovative Computing Technology (INTECH 2013), 2013.
[2] Kugler P., Schlarb H., Blinn J., Picard A., Eskofier B.: A Wireless Trigger for synchronization of Wearable Sensor to External System during Recording of Human Gait, Conf Proc IEEE Eng Med Biol Soc, 2012.
[3] Komisar V., Novak A.C., Haycock B. A novel method for synchronizing motion capture with other data sources for milliseconds-level precision, Gait Posture, 2017.
[4] Krzysiak K.: Sieci komputerowe. Kompendium. Wydanie II Helion, 2015.
[5] LaValle S.: Planning Algorithms, Cambridge University Press, 2006.
[6] Bułka D., ĝwider P.: Model pojazdu zastosowany w programie V-SIM do symulacji ruchu i zderzeń pojazdów samochodowych, Zeszyty Naukowe Politechniki Świętokrzyskiej. Mechanika, 2004.
[7] https://stackoverflow.com/questions/32466314/apple-watchcmdevicemotion-is-not-giving-me-good-readings [18.11.2018]
[8] Evans P.: Rotations and rotation matrices, Acta Crystallographica Section D Biological Crystallography, 2001.
[9] http://www.cplusplus.com/reference/cmath/atan/ [18.11.2018]
[10] http://www.cplusplus.com/reference/cmath/atan2/?kw=atan2 [18.11.2018]

Published
2019-03-30

Cited by

Walczyna, K., Jasiński, B., Smołka, J., & Miziołek, M. (2019). Recording using a motion capture system and a mobile device with synchronization of the recording triggering . Journal of Computer Sciences Institute, 10, 5–11. https://doi.org/10.35784/jcsi.184

Authors

Karol Walczyna 
karolwalczyna@outlook.com
Lublin University of Technology Poland

Authors

Bartosz Jasiński 

Lublin University of Technology Poland

Authors

Jakub Smołka 

Lublin University of Technology Poland

Authors

Mateusz Miziołek 

Lublin University of Technology Poland

Statistics

Abstract views: 187
PDF downloads: 219