METHODS FOR DETECTING FIRES IN ECOSYSTEMS USING LOW-RESOLUTION SPACE IMAGES

Valerii Shvaiko

valshvaiko57@gmail.com
The National Technical University of Ukraine ”Igor Sikorsky Kyiv Polytechnic Institute”, Heat Power Engineer Department, Automation of Projection of Power Processes and Systems (Ukraine)
http://orcid.org/0000-0002-9304-8710

Olena Bandurka


The National Technical University of Ukraine ”Igor Sikorsky Kyiv Polytechnic Institute”, Heat Power Engineer Department, Automation of Projection of Power Processes and Systems (Ukraine)
http://orcid.org/0000-0002-8059-1861

Vadym Shpuryk


The National Technical University of Ukraine ”Igor Sikorsky Kyiv Polytechnic Institute”, Heat Power Engineer Department, Automation of Projection of Power Processes and Systems (Ukraine)
http://orcid.org/0000-0002-3477-5731

Yevhen V. Havrylko


The National Technical University of Ukraine ”Igor Sikorsky Kyiv Polytechnic Institute”, Heat Power Engineer Department, Automation of Projection of Power Processes and Systems (Ukraine)
http://orcid.org/0000-0001-9437-3964

Abstract

The paper presents the methods for fire identification using low-resolution space images obtained from Terra Modis and NOAA satellites. There are lots of algorithms to identify potentially "fire pixels" (PF). They are based on the assessment of temperature in spectral ranges from 3.5–4 to 10.5–11.5 microns. One of the problematic aspects in the Fire Detection Method using low-resolution space images is "Cloud and Water Masking". To identify "fire pixels", it is important to exclude from the analysis fragments of images that are covered with clouds and occupied by water objects. Identification of pixels in which one or more fires are actively burning at the time of passing over the Earth is the basis of the algorithm for detecting potentially "fire pixels". The algorithm requires a significant increase in radiation in the range of 4 micrometers, as well as on the observed radiation in the range of 11 micrometers. The algorithm investigates each pixel in a scene that is assigned one of the following classes as a result: lack of data, cloud, water, potentially fire or uncertain. The pixels that lack actual data are immediately classified as "missing data (NULL)" and excluded from further consideration. Cloud and water pixels, defined by the cloud masking technique and water objects, belong to cloud and water classes, respectively. The fire detection algorithm investigates only those pixels of the Earth's surface that are classified as potentially fire or uncertain. The method was implemented using the Visual Programming Tool PowerBuilder in the data processing system of Erdas Imaging. As a result of the use of the identification method, fires in the Chornobyl exclusion zone, steppe fires and fires at gas wells were detected. Using the method of satellite fire identification is essential for the prompt detection of fires for remote forests or steppes that are poorly controlled by ground monitoring methods.


Keywords:

environmental security, ecosystem fires in Ukraine, remote sensing, GIS

Chandra А. М., Gosh S. K.: Remote sensing and geographic information systems. Tecnosfera, Moscow 2008.
  Google Scholar

Griffiths P. et al.: Forest disturbances, forest recovery, and changes in forest types across the Carpathian ecoregion from 1985 to 2010 based on Landsat image composites. Remote Sensing of Environment 151/2014, 72–88.
DOI: https://doi.org/10.1016/j.rse.2013.04.022   Google Scholar

Justice C. O. et al.: Robust statistics. Wiley, New York 2002.
  Google Scholar

Kaufman Y. J., Justice C. O., Flynn L. P., Kendall J. D., Prins E. M., Giglio L., Ward D. E., Menzel W. P., Setzer A. W.: Potential global fire monitoring from EOS-MODIS. Journal of Geophysical Research 103(D24)/1998, 32215–32238.
DOI: https://doi.org/10.1029/98JD01644   Google Scholar

Kashkin V. B., Suchinin А. I.: Remote sensing of the Earth from space. Digital imaging. Logos, Moscow 2001.
  Google Scholar

Krycuk S. G.: Mapping boreal forests using satellite data. Modern problems of remote sensing of the Earth from space 9(4)/2012, 255–264.
  Google Scholar

Morisette J. T. et al.: Identification of subresolution high temperature sources using a thermal IR sensor. Photogrammetric Engineering and Remote Sensing 47/2003, 1311–1318.
  Google Scholar

Morissette, J. T. et al.: Validation of the MODIS active fire product over Southern Africa with ASTER data. International Journal of Remote Sensing 26(19)/2002, 4239–4264.
DOI: https://doi.org/10.1080/01431160500113526   Google Scholar

Seielstad C. A. et al.: MODIS level 1A Earth location: Algorithm theoretical basis document version 3.0. SDST-092, MODIS Science Data Support Team 2002.
  Google Scholar

Stroppiana D. et al.: Testing the sensitivity of a MODIS-like daytime active fire detection model in Alaska using NOAA/AVHRR infrared data. Photogrammetric Engineering and Remote Sensing 68/2000, 831–838.
  Google Scholar

Strugailo V. V.: Review of methods of filtering and segmentation of digital images. Science and education 5/2012, 270–281.
DOI: https://doi.org/10.7463/0512.0411847   Google Scholar

Vyshnjakov V. J., Tkachuk P. A.: Features of methods for determining temperature anomalies according to remote sensing MODIS (TERRA) and AVHRR (NOAA). Estimates of their quality. Ecological safety and nature management 10/2012, 81–90.
  Google Scholar

Zibcev S. V., Myronjuk V. V.: Methodical recommendations from MODIS and Landsat for monitoring of forest fires: Recommendations for forestry enterprises. NUBandN, Kiev 2015.
  Google Scholar

Download


Published
2021-03-31

Cited by

Shvaiko, V., Bandurka, O., Shpuryk, V., & Havrylko, Y. V. (2021). METHODS FOR DETECTING FIRES IN ECOSYSTEMS USING LOW-RESOLUTION SPACE IMAGES. Informatyka, Automatyka, Pomiary W Gospodarce I Ochronie Środowiska, 11(1), 15–19. https://doi.org/10.35784/iapgos.2576

Authors

Valerii Shvaiko 
valshvaiko57@gmail.com
The National Technical University of Ukraine ”Igor Sikorsky Kyiv Polytechnic Institute”, Heat Power Engineer Department, Automation of Projection of Power Processes and Systems Ukraine
http://orcid.org/0000-0002-9304-8710

Authors

Olena Bandurka 

The National Technical University of Ukraine ”Igor Sikorsky Kyiv Polytechnic Institute”, Heat Power Engineer Department, Automation of Projection of Power Processes and Systems Ukraine
http://orcid.org/0000-0002-8059-1861

Authors

Vadym Shpuryk 

The National Technical University of Ukraine ”Igor Sikorsky Kyiv Polytechnic Institute”, Heat Power Engineer Department, Automation of Projection of Power Processes and Systems Ukraine
http://orcid.org/0000-0002-3477-5731

Authors

Yevhen V. Havrylko 

The National Technical University of Ukraine ”Igor Sikorsky Kyiv Polytechnic Institute”, Heat Power Engineer Department, Automation of Projection of Power Processes and Systems Ukraine
http://orcid.org/0000-0001-9437-3964

Statistics

Abstract views: 429
PDF downloads: 180


Most read articles by the same author(s)