NEEDLE DETECTOR OF X-RAY AND GAMMA RADIATION

Grzegorz Domański

G.Domanski@ire.pw.edu.pl
Warsaw University of Technology, The Institute of Radioelectronics and Multimedia Technology (Poland)

Roman Szabatin


Warsaw University of Technology, The Institute of Radioelectronics and Multimedia Technology (Poland)

Piotr Brzeski


Warsaw University of Technology, The Institute of Radioelectronics and Multimedia Technology (Poland)

Bogumił Konarzewski


Warsaw University of Technology, The Institute of Radioelectronics and Multimedia Technology (Poland)

Abstract

The article presents the developed structure of the novel needle proportional gas detector (NPC – Needle Proportional Counter) used for the detection of X-rays and gamma rays. The advantage of the detector is its simple mechanical construction and the possibility of detection of incident radiation in a direction parallel to the needle. The measured energy spectrum of the isotope Fe-55 by means of the developed detector is presented. 


Keywords:

gas detector with electron multiplication, x-ray detector, gamma radiation

Borkhari A.F., Yasserian K.: Influence of the hot filament on the electrical breakdown characteristics in the presence of Ar/N2. Journal of Theoretical and Applied Physics, 7/2013.
  Google Scholar

Charpak G., Bouclier R., Bressani T., Favier J., Zupančič Č.: The use of multiwire proportional counters to select and localize charged particles. Nuclear Instruments and Methods, 62(3)/1968, 262–268.
  Google Scholar

Geiger H., Müller W.: Das Elektronenzählrohr, Physikalische Zeitshrift, 29/1928, 839–841.
  Google Scholar

Ketzer B., Bachmann S., Cape M., Deutel M., Friedrich J., Kapple S., Konorov I., Placci A., Reisinge K., Ropelewski L., Shekhtman L., Sauli F.: GEM detectors for COMPASS. IEEE Transaction on Nuclear Science, 48/2001, 1065–1069.
  Google Scholar

Knoll Glenn F.: Radiation Detection and Measurement. John Wiley and Sons, New York, 1999.
  Google Scholar

Oed A.: Position-sensitive detector with microstrip anode for electron multiplication with gases. Nuclear Instruments and Methods, A263/1988, 351–359.
  Google Scholar

Rutherford E., Geiger H.: An electrical method of counting the number of alpha particles from radioactive substances. Proceedings of the Royal Society A81/1908, 141–161.
  Google Scholar

Sauli F.: GEM A new concept for electron amplification in gas detectors. Nuclear Instruments and Methods in Physics Research, 386/1997, 531–534.
  Google Scholar

Yun Z.L., Bin C., Yiming Z.: Fabrication of anti-reflective micro-structure at terahertz frequency by using Chinese acupuncture needles. Optics Letters, 2015, 2917–2920.
  Google Scholar

Download


Published
2017-03-03

Cited by

Domański, G. ., Szabatin, R., Brzeski, P., & Konarzewski, B. (2017). NEEDLE DETECTOR OF X-RAY AND GAMMA RADIATION. Informatyka, Automatyka, Pomiary W Gospodarce I Ochronie Środowiska, 7(1), 121–124. https://doi.org/10.5604/01.3001.0010.4599

Authors

Grzegorz Domański 
G.Domanski@ire.pw.edu.pl
Warsaw University of Technology, The Institute of Radioelectronics and Multimedia Technology Poland

Authors

Roman Szabatin 

Warsaw University of Technology, The Institute of Radioelectronics and Multimedia Technology Poland

Authors

Piotr Brzeski 

Warsaw University of Technology, The Institute of Radioelectronics and Multimedia Technology Poland

Authors

Bogumił Konarzewski 

Warsaw University of Technology, The Institute of Radioelectronics and Multimedia Technology Poland

Statistics

Abstract views: 177
PDF downloads: 50


Most read articles by the same author(s)