DEVELOPMENT OF ELECTRICAL CAPACITANCE TOMOGRAPH DESIGN IN THE NUCLEAR AND MEDICAL ELECTRONICS DIVISION
Jacek Kryszyn
J.Kryszyn@ire.pw.edu.plWarsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division (Poland)
Waldemar Smolik
Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division (Poland)
Tomasz Olszewski
Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division (Poland)
Roman Szabatin
Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division (Poland)
Abstract
Electrical Capacitance Tomography is a technique which allows to visualize a spatial distribution of electric permittivity in an examined volume. ECT allows to achieve hundreds of frames per second which is suitable for the industrial application, e.g. monitoring of multiphase flows or material mixing. Construction of such ECT system which enables precise data acquisition with sufficient speed is a challenge. In the Division of Nuclear and Medical Electronics ECT systems which have found applications in many research facilities in Poland and all over the world have been constructed for over 15 years. In this article a multichannel ET3 tomograph and its successor,EVT4, are presented. EVT4 will allow to obtain more than 10 thousand frames per second. This will allow to make progress in studies of dynamic processes and 3D visualization.
Keywords:
electrical capacitance tomographyReferences
Brzeski P., Mirkowski J., Olszewski T., Pląskowski A., Smolik W., Szabatin R.: Multichannel capacitance tomograph for dynamic process imaging. Opto-Electronics Review, 11(3), 2003, 175–180.
Google Scholar
Huang S.M., Plaskowski A., Xie C.G., Beck M.S.: Capacitance-based tomographic flow imaging system. Electron. Lett., 24, 7/1988, 418–419.
Google Scholar
Jaworski A.J., Dyakowski T.: Application of electrical capacitance tomography for measurement of gas-solid flow characteristics in a pneumatic conveying system. Meas. Sci. Technol., 12/2001, 1109–1119.
Google Scholar
Kryszyn J., Smolik W., Olszewski T., Szabatin R.: Elektryczny tomograf pojemnościowy EVT4. Elektronika – konstrukcje, technologie, zastosowania, 7/2015, 12–15.
Google Scholar
Kryszyn J., Smolik W., Szabatin R., Olszewski T.: Preliminary Measurements with FPGA-based Electrical Capacitance. 7th International Symposium on Process Tomography, Dresden, Germany, 2015.
Google Scholar
Plaskowski A., Beck M., Thorn R., Dyakowski T.: Imaging industrial flows. Applications of electrical process tomography, IOP Publishing Ltd., 1995.
Google Scholar
Yang W.Q.: Hardware design of electrical capacitance tomography systems. Meas. Sci. Technol., 7/1996, 225–232.
Google Scholar
Authors
Jacek KryszynJ.Kryszyn@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division Poland
Authors
Waldemar SmolikWarsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division Poland
Authors
Tomasz OlszewskiWarsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division Poland
Authors
Roman SzabatinWarsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division Poland
Statistics
Abstract views: 275PDF downloads: 52
License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Most read articles by the same author(s)
- Grzegorz Domański, Roman Szabatin, Piotr Brzeski, Bogumił Konarzewski, NEEDLE DETECTOR OF X-RAY AND GAMMA RADIATION , Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska: Vol. 7 No. 1 (2017)