ROZWÓJ KONSTRUKCJI ELEKTRYCZNEGO TOMOGRAFU POJEMNOŚCIOWEGO W ZAKŁADZIE ELEKTRONIKI JĄDROWEJ I MEDYCZNEJ

Jacek Kryszyn

J.Kryszyn@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division (Polska)

Waldemar Smolik


Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division (Polska)

Tomasz Olszewski


Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division (Polska)

Roman Szabatin


Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division (Polska)

Abstrakt

Elektryczna tomografia pojemnościowa pozwala na obrazowanie przestrzennego rozkładu przenikalności elektrycznej w badanej objętości. Technika ta pozwala na uzyskanie setek obrazów na sekundę, dzięki czemu istnieje możliwość wykorzystania jej w przemyśle, na przykład do monitorowania procesów dynamicznych, takich jak przepływy wielofazowe lub mieszanie materiałów. Skonstruowanie systemu tomograficznego pozwalającego na bardzo szybką akwizycję obrazów o dobrej jakości jest jednak dużym wyzwaniem. W Zakładzie Elektroniki Jądrowej i Medycznej Politechniki Warszawskiej od lat powstają konstrukcje tomografów pojemnościowych, które znajdowały zastosowanie w placówkach naukowych w Polsce i na świecie. W tym artykule prezentowany jest wielokanałowy tomograf ET3 oraz jego następca, EVT4, który pozwoli na uzyskiwanie 10 tysięcy obrazów na sekundę. Pozwoli to na dokładniejsze badanie procesów dynamicznych oraz wizualizację trójwymiarową.


Słowa kluczowe:

elektryczna tomografia pojemnościowa

Brzeski P., Mirkowski J., Olszewski T., Pląskowski A., Smolik W., Szabatin R.: Multichannel capacitance tomograph for dynamic process imaging. Opto-Electronics Review, 11(3), 2003, 175–180.
  Google Scholar

Huang S.M., Plaskowski A., Xie C.G., Beck M.S.: Capacitance-based tomographic flow imaging system. Electron. Lett., 24, 7/1988, 418–419.
  Google Scholar

Jaworski A.J., Dyakowski T.: Application of electrical capacitance tomography for measurement of gas-solid flow characteristics in a pneumatic conveying system. Meas. Sci. Technol., 12/2001, 1109–1119.
  Google Scholar

Kryszyn J., Smolik W., Olszewski T., Szabatin R.: Elektryczny tomograf pojemnościowy EVT4. Elektronika – konstrukcje, technologie, zastosowania, 7/2015, 12–15.
  Google Scholar

Kryszyn J., Smolik W., Szabatin R., Olszewski T.: Preliminary Measurements with FPGA-based Electrical Capacitance. 7th International Symposium on Process Tomography, Dresden, Germany, 2015.
  Google Scholar

Plaskowski A., Beck M., Thorn R., Dyakowski T.: Imaging industrial flows. Applications of electrical process tomography, IOP Publishing Ltd., 1995.
  Google Scholar

Yang W.Q.: Hardware design of electrical capacitance tomography systems. Meas. Sci. Technol., 7/1996, 225–232.
  Google Scholar


Opublikowane
2017-03-03

Cited By / Share

Kryszyn, J. ., Smolik, W., Olszewski, T. ., & Szabatin, R. . (2017). ROZWÓJ KONSTRUKCJI ELEKTRYCZNEGO TOMOGRAFU POJEMNOŚCIOWEGO W ZAKŁADZIE ELEKTRONIKI JĄDROWEJ I MEDYCZNEJ . Informatyka, Automatyka, Pomiary W Gospodarce I Ochronie Środowiska, 7(1), 111–114. https://doi.org/10.5604/01.3001.0010.4597

Autorzy

Jacek Kryszyn 
J.Kryszyn@ire.pw.edu.pl
Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division Polska

Autorzy

Waldemar Smolik 

Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division Polska

Autorzy

Tomasz Olszewski 

Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division Polska

Autorzy

Roman Szabatin 

Warsaw University of Technology, Faculty of Electronics and Information Technology, The Institute of Radioelectronics and Multimedia Technology, Nuclear and Medical Electronics Division Polska

Statystyki

Abstract views: 190
PDF downloads: 44


Inne teksty tego samego autora

<< < 1 2