Analysis of the distribution of temperature and humidity in different variants of external walls made of hemp-lime composite
Anna Alberska
Department of Construction; Faculty of Civil Engineering and Architecture; Lublin University of Technology; (Poland)
Przemysław Brzyski
p.brzyski@pollub.plDepartment of Construction; Faculty of Civil Engineering and Architecture; Lublin University of Technology; (Poland)
https://orcid.org/0000-0001-9533-7535
Abstract
Proper design of the building component, which not only meets the legal requirements, but also provides comfort of using of buildings, requires knowledge of the materials and solutions. Since moisture is one of the main factors that can affect the building structure destruction, it is particularly important to be aware of hygrothermal properties of components. And this is the focus of the study. In this paper several variants of external walls were analysed, according to the requirements in terms of: heat transfer coefficient U, the risk of surface and interstitial condensation. Partitions were designed with composite based on shives from industrial hemp and lime binder, which is not yet widely used in Poland. The purpose of the analysis of this material was to prove the validity of using the natural materials in residential buildings.
Keywords:
condensation, thermal conductivity, moisture, industrial hemp, limeReferences
Stanwix W., Sparrow A., The Hempcrete Book – Designing and building with hemp-lime. England, Green Books, 2014.
Google Scholar
www.japanhemp.org/en/miasahouse.htm
Google Scholar
Allin S., Building with Hemp. Ireland, Seed Press, 2012.
Google Scholar
Bevan A., Woolley T., Hemp lime construction – A guide to building with hemp lime composites, England, BRE Press, 2008.
Google Scholar
Evrard A., Sorption behaviour of Lime-Hemp Concrete and its relations to indoor comfort and energy demand, The 23rd Conference on Passive and Low Energy Architecture, Geneva, 2006.
Google Scholar
Firląg S., Szczelność powietrzna budynków pasywnych i energooszczędnych – wyniki badań. Czasopismo Techniczne Budownictwo, 2-B (2012) 107-113.
Google Scholar
Booklet: The Thermal Performance of Tradical Hemcrete.
Google Scholar
EN ISO 6946:2007: Building components and building elements – Thermal resistance and thermal transmittance – Calculation method.
Google Scholar
Rozporządzenie Ministra Infrastruktury z dnia 12 kwietnia 2002 r. w sprawie warunków technicznych, jakim powinny odpowiadać budynki i ich usytuowanie (Dz. U. Nr 75, poz. 690, ze zmianami z dnia 5 lipca 2013 r.).
Google Scholar
Treść Programu priorytetowego Narodowego Funduszu Ochrony Środowiska i Gospodarki Wodnej „Poprawa efektywności energetycznej”.
Google Scholar
ISO 13788:2012 „Hygrothermal performance of building components and building elements. Internal surface temperature to avoid critical surface humidity and interstitial condensation. Calculation methods”, International Organization for Standardization, Switzerland.
Google Scholar
www.mir.gov.pl/strony/zadania/budownictwo/dane-do-swiadectw-charakterystyki-energetycznej-budynkow
Google Scholar
Dylla A., Praktyczna fizyka cieplna budowli. Bydgoszcz, Wydawnictwa uczelniane UTP, 2009.
Google Scholar
Authors
Anna AlberskaDepartment of Construction; Faculty of Civil Engineering and Architecture; Lublin University of Technology; Poland
Authors
Przemysław Brzyskip.brzyski@pollub.pl
Department of Construction; Faculty of Civil Engineering and Architecture; Lublin University of Technology; Poland
https://orcid.org/0000-0001-9533-7535
Statistics
Abstract views: 229PDF downloads: 135
License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Budownictwo i Architektura supports the open science program. The journal enables Open Access to their publications. Everyone can view, download and forward articles, provided that the terms of the license are respected.
Publishing of articles is possible after submitting a signed statement on the transfer of a license to the Journal.