THE STRUCTURAL ANALYSIS OF SOCKET INLAYS OF THE HIP ENDOPROSTHESIS

Robert Karpiński

r.karpinski@pollub.pl
Lublin University of Technology, Faculty of Electrical Engineering and Computer Science (Poland)

Łukasz Jaworski


Poznan University of Technology, Faculty of Mechanical Engineering and Management (Poland)

Abstract

The paper presents results of the preliminary structural analysis of socket inlays model of the endoprosthesis of the hip joint. Basics of anatomy and biomechanical analysis of the hip joint were introduced. The prototype of socket inlay of the hip endoprosthesis was modeled using Solid Edge ST8 software. After determining physical properties of structural materials for socket inlays, the Finite Elements Analysis of the model was conducted using SolidWorks software under various load conditions. Finally the results of analysis were presented.


Keywords:

endoprosthesis, finite element method, FEM, hip joint, socket inlay

R. Karpiński, Ł. Jaworski, J. Szabelski,"The design and structural analysis of the endoprosthesis of the hip joint," Applied Computer Science, vol. 12, no. 1, pp. 87–95, 2016.
  Google Scholar

R. Karpiński, Ł. Jaworski, J. Zubrzycki, "Structural analysis of articular cartilage of the hip joint using finite element method," Adv. Sci. Technol. Res. J., vol. 10, no. 31, pp. 240–246, 2016.
DOI: https://doi.org/10.12913/22998624/64064   Google Scholar

A. S. Dickinson, M. Browne, K. C. Wilson, J. R. T. Jeffers, A. C. Taylor, "Pre-clinical evaluation of ceramic femoral head resurfacing prostheses using computational models and mechanical testing," Proc. IMechE Part H: J. Engineering in Medicine, vol. 225, no. 9, pp. 866–876, 2011.
DOI: https://doi.org/10.1177/0954411911411605   Google Scholar

H. Fang, S. M. Hsu, J. V. Sengers, Ultra-High Molecular Weight Polyethylene Wear Particle Effects on Bioactivity.Washington DC: U.S. Government Printing Office, 2003.
DOI: https://doi.org/10.6028/NIST.SP.1002   Google Scholar

M.Braniewska, J.Zubrzycki, R.Karpiński: Komputerowo wspomagane projektowanie i wytwarzanie implantu stawu biodrowego. Innowacje w fizjoterapii, 2, 2015, 147–170.
  Google Scholar

Download


Published
2016-12-26

Cited by

Karpiński, R., & Jaworski, Łukasz. (2016). THE STRUCTURAL ANALYSIS OF SOCKET INLAYS OF THE HIP ENDOPROSTHESIS. Journal of Technology and Exploitation in Mechanical Engineering, 2(1), 36–39. https://doi.org/10.35784/jteme.515

Authors

Robert Karpiński 
r.karpinski@pollub.pl
Lublin University of Technology, Faculty of Electrical Engineering and Computer Science Poland

Authors

Łukasz Jaworski 

Poznan University of Technology, Faculty of Mechanical Engineering and Management Poland

Statistics

Abstract views: 184
PDF downloads: 143


License

All articles published in this journal are open access and distributed under the terms of the Creative Commons Attribution 4.0 International License.