The tune of mass dampers for the Municipal Stadium in Poznan

Piotr Wielgos


Department of Structural Mechanics; Faculty of Civil Engineering and Architecture; Lublin University of Technology (Poland)
https://orcid.org/0000-0003-3548-9945

Abstract

This paper presents the issues related to the design of the multiple tuned mass dampers (MTMD) for the Municipal Stadium in Poznan. It is focused on the design issues, in particular the selection of parameters of mass dampers, their location at the main structure (in this case the full modal analysis was carried out) and the optimization of dampers parameters (the optimization algorithm DAMP-SYM application was used). The verification of the assumptions made during the design stage was carried out, taking into account the dynamic tests of TMD as well as the measurements on the real object of Municipal Stadium in Poznan.


Keywords:

dynamic analysis, tuned mass damper, optimisation

Igusa T., Xu K. Vibration control using multiple tuned mass dampers. Journal of Sound and Vibration 175, Issue 4 (1994) 491–503.
  Google Scholar

Zhang R. H., Soong T. T. .Seismic design of viscoelastic dampers for structural applications. Journal of Structural Engineering 118 (1992) 1375–1392.
  Google Scholar

Li H. N, Ni X. L..Optimization of non–uniformly distributed multiple tuned mass damper. Journal of Sound and Vibration 308, Issues 1–2 (2007) 80–97.
  Google Scholar

Flaga, A., Wielgos, P. Zagadnienia optymalizacji parametrów wielokrotnych strojonych tłumików masowych. Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika 74 [258] (2008) 73–84.
  Google Scholar

P. Wielgos, A. Flaga. The optimisation of multiple tuned mass dampers parameters. The theoretical basis and numerical examples in: Recent Advances in Research on Environmental Effects on Buildings and People. (ed. Flaga A., Lipecki T.) Polish Association For Wind Engineering, Cracow 2010, s.423-432.
  Google Scholar

Wielgos P. Rozprawa doktorska: Ocena skuteczności działania wielokrotnych, strojonych tłumików masowych w konstrukcjach budowlanych; Politechnika Lubelska; Lublin 2010.
  Google Scholar

Z. Siekierda, A. Flaga, P. Wielgos, T. Lipecki, Tuned mass dampers with elastomeric limiters. Theory and research in: Recent Advances in Research on Environmental Effects on Buildings and People. (ed. Flaga A., Lipecki T.) Polish Association For Wind Engineering, Cracow, Poland 2010,s. 433-442.
  Google Scholar

Bendat J., Piersol A. Metody analizy i pomiaru sygnałów losowych, PWN, Warszawa 1976.
  Google Scholar


Published
2013-03-11

Cited by

Wielgos, P. (2013) “The tune of mass dampers for the Municipal Stadium in Poznan”, Budownictwo i Architektura, 12(1), pp. 291–298. doi: 10.35784/bud-arch.2212.

Authors

Piotr Wielgos 

Department of Structural Mechanics; Faculty of Civil Engineering and Architecture; Lublin University of Technology Poland
https://orcid.org/0000-0003-3548-9945

Statistics

Abstract views: 178
PDF downloads: 134


License

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Budownictwo i Architektura supports the open science program. The journal enables Open Access to their publications. Everyone can view, download and forward articles, provided that the terms of the license are respected.

Publishing of articles is possible after submitting a signed statement on the transfer of a license to the Journal.